The HiTECH Liquid Density Monitor utilizing Penetrating Pulse Technology is the only no-contact, on-line, real-time, non-intrusive liquid density monitor that accurately measures density of process liquids without sampling or bypass piping.

Applications:

Liquid Density

Concentration Monitor

acids, caustics, starch,
sugar, alcohol, milk, etc.

Petroleum / refinery analyzer

Liquefied Gas (LNG, LPG, etc) monitor

Advantages:
Non-Contact 
sensor mounted outside of vessel

Penetrating Pulse Technology
low-cost & non-hazardous vs. nuclear

Penetrating Pulse Technology  
low-cost & non-hazardous vs. nuclear

Easy installation on existing pipes - no downtime.

High long-term stability ~ Maintenance-free operation

Measurement of ~
toxic, corrosive and aggressive materials

Explosion protection (optional)
EEx d II B T 5 and EEx d II C T 6

Technical Data

Principle Penetrating Pulse Technology through the wall measurement.
Mounting Outside of vessel or pipe.
Cable length to the sensor up to 980 feet
Resolution

1 % of the measuring area
1 kg/m³
Concentration: 

0.07 % (saline)
0.2% (sugar solution)

Container material Steel, Stainless Steel, Enameled Steel, Other Metals, Glass, Plastics
Adjustments Digital - Parameters set from keyboard and integrated display or via the serial interface.
Relay Output Contact (closing), max. 250 V / 5 A.
Interface Serial RS 485 interface.
Current output 4...20 mA, invertible, isolated.
Power supply 19 ... 30 V AC/DC, 500 mA, approx. 3 s response time after applying operating voltage.
Enclosure

Electronics: plastic, 100 x 75 x 100 mm, IP 20.
Sensors: aluminum, 103 x 75 x 92 mm, IP 65

Electrical connections Screw Connections.
Temperature range Electronics: -20 ... +70°C.
Sensors: -20 ... + 135°C.

301 Oxford Valley Road, Building 505 · Yardley, PA 19067-7711 · Phone: 1-866-DR-LEVEL· Fax: 215-321-6067 · E-mail: